•Current Sesitivity: 15 pA. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF Product Support Resources. 8 MS/s. If the NI-DAQmx connected to the USB is running buffer collection or is accidentally terminated when generating tasks, it may cause the system to crash, and the computer will restart or display the Windows Kernel panic check (that is, the blue screen for crashes). It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 66 KB NI-PXIe-4163 Datasheet 308. Member. PXIe-4142 (782430-01) PXI Express: 4: 3. ni pxie-1085シャーシにおけるpxiトリガバスの接続図。 PXI周辺モジュールへのトリガの転送方法を表している。 電気的仕様では、高い性能が要求されるアプリケーションに向けて、PXIシステムに高性能の同期機能を加えるPXIスタートリガネットワークについて. Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files; Four-quadrant source and measure capability; Up to 408 channels in a 4U, 19-inch PXI chassis;The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The PXIe-4140 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. In. Table 1. com | PXIe-4142 Specifications PXIe-4142 (40W) 3. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. Flexible delivery options, including pick-up and delivery, local drop-off. InstrumentStudio 2022 Q4 Readme. Set the level on the NI 4142 to the first specified test point. Manuals. 115 2. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The PXIe-5841 features the flexibility of a software defined radio architecture with RF. Find new, used, and rental NI PXIe-4139 PXIe-4139 System SMU with Source Adapter Technology 782856-02 at Electro Rent. 2 For increased capability, NI recommends installing the PXIe-4147 in a chassis with slot cooling capacity ≥58 W. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Diversified models and products, and all kinds of rare and discontinued products 4. Feature Usage. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 15 days free replacement for quality problemsView online or download 1 Manuals for National Instruments NI PXIe-4142. NI GPIBコントロー. 2 Channels are isolated from earth ground but share a. Work with. View in Order History. com | NI PXIe-4142 Calibration Procedure. Member. Products Manufacturers Services Solutions. are not included with this equipment unless. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. from ctypes import c_bool, c_int, c_double,. Only combine channels of the same instrument. PXIe-4142 Connector Pinout. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. 8 x 5. Part Number: 783761-01. Refer to the NI. Important Notice: Other accessories, manuals, cables, calibration. PXIe-5673E Controller module, NI, PXIe-5673E Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. The recommendation applies to all PXIe-414 X SMUs. PXIe-4140は、ピン数の多いアプリケーションに最適な4チャンネルソースメジャーユニット(SMU)です。 このSMUは4象限動作が可能で、各チャンネルにリモート(4. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. You can request. The NI-DCPower API has a VI called Export Signal VI which I could use for exporting the trigger signal into a specific line when "Source Complete Event" happens on my SMU. pxie-4142 pxie-4143 pxie-4144 pxie-4145 ni smu数字化仪(示波器)的功能是什么? 如何使用? 如何达到ni smu的最大采样率? ni smu的数字化仪功能对于捕获smu详细的瞬态响应特性或表征待测设备(dut)响应(例如线性调整率和负载调整率)至关重要。. 3 V rail and 2. PXIe-4142. Solution Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary waveform to a continuous output sequence with voltage levels and source delays (corrected by the intersample delays of the. 5 driver. Order Quantity: 100 Piece/Pieces. ni pxie-4139の特徴は構成可能な過渡応答設定で、出力制御ループの負荷補正が柔軟に行える。 NIオンラインカタログ にアクセスして、SourceAdaptでフィルタリングすれば、SourceAdaptテクノロジをサポートしているNI PXIソースメジャーユニットを確認すること. PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit. Member. Has been engaged in industrial control industry for a long time, with a large number of inventories. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 88]-4. Electro Rent Remains Ready and Available to Support Customers Through COVID-19 Challenges. 11. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. •Current Sesitivity: 1 pA. October 2022. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; PXIe-4147; PXIe-4154; NI 416x SMUs. About National Instruments. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Re: Recommended approach for PXI control from Python. View and Download National Instruments NI PXIe-4140 getting started manual online. The PXIe-4144 (Part Number: 782432-01) has a Wireless Testing System (RFIC) that incorporates the key instruments the user needs to describe control intensifiers, transceivers, IF receivers, RF fronts, modulators/demodulators, and other RFIC gadgets. The mold piece adopts four quadrant operation mode, each channel integrates the remote sense line (4) transfer function to realize the accurate measurement. After a set time i take a voltage measurement, which should reflect the capacitance. PXIe-4139; PXIe-4140; PXIe-4141; PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; PXIe-4154; Non-NI-DAQmx-Based Power Supplies and SMUs. Complies with the essential requirements of the following applicable UK Regulations: Electromagnetic Compatibility (EMC) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic. 2. pxie-2512 PXIE-1435 Company advantage service: 1. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. TobiasG. NI PXIe-4142 technical details. Diversified models and products, and all kinds of rare and discontinued products 4. •Source Adapt: No. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. Nabízí provoz ve 4 kvadrantech, každý kanál má integrované vzdálené (4 - wire) snímání pro přesná měření. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). It combines vector signal generator, vector signal analyzer and high-speed serial interface capabilities with FPGA-based real-time signal processing and control. Please contact Artisan Technology Group Sales for configuration pricing and availability. You are browsing the BE_FR site. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis6570 Compatibility with Third-party PXI Controller. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI cannot be reconfigured from a dialog box. 066 [77. 65]. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 3 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA Figure 1. The module can maximize. PXI-7842R Controller module, NI, PXI-7842R Controller module PXI-7842R Controller module Module Clips Drive controller servo motor Contact: Mr. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). 553. 0 Kudos Message 11 of 15 (1,626 Views) Reply. Fornisce operatività a 4 quadranti e ogni canale include sensori integrati per la misura in remoto (4 fili) per misure accurate. The PXIe‑4138 (Part Number: 782856-01) Source Measure Unit (SMU) conveys high power, exactness, and speed. Work with our experts to sustain your critical applications. : Other accessories, manuals, cables, calibration data, software, etc. PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator;The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Table 1. NI. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. NIの集録および信号調整デバイスをサポートします。. •Source Adapt: Yes. Vysoká vzorkovací frekvence PXIe-4142 může redukovat dobu měření, zachycovat mžikové charakteristiky zařízení a umožnit rychlou I V. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The PXIe-5842 combines a vector signal generator and vector signal analyzer with FPGA-based, real-time signal processing and control. Refer to the NI. Added support for the PXIe-4139(40W) source measure unit, newly supported in NI-DCPower 20. PXIe-4142 è una SMU (System Source Measure Unit) a 4 canali ideale per applicazioni con numero di pin elevato. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXI Source Measure Unit. PXI System Source Measure Units. com. Fast Quotes & Shipping. Follow the instructions in the installation prompts. PXIe-4145. 8 Channels are isolated from earth ground but share a common LO. 尽管未将DCPower和SMU卡(如PXIe-4139)设计为用作功能或波形发生器,但可以通过将所需的频率和幅度或预定义的. The NI PXIe-4139 features configurable transient response settings for flexible load compensation of the output control loop. PXIe-4142 Quadrant Diagram, All Channels Quadrant I Source I± ±24 V 150 mA I+ V± V+ 24 V Quadrant IV Sink Quadrant III Source ±150 mA Quadrant II Sink Limit power sinking to 6 W per module. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 15 days free replacement for quality problemsPXI-4462 Data acquisition card, NI, PXI-4462 Data acquisition card PXI-4462 Data acquisition card Module Clips Drive controller servo motor Contact: Mr. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXI Source Measure Unit 驱动. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. Follow the steps below to programmatically route a SMU signal to a PXI_TRIG line: Place a niDCPower Initialize With Channels VI on the Block Diagram. Email: info@artisantg. custom applications within an application programming interface (API). 150660B-02L or later PXIe-4141 Flex SMU: 10V, 100 mA 150660B-03L or later PXIe-4141 Flex SMU: 10V, 100 mA w/ High Sense Resistance 153690A-01L or later PXIe-4142 Flex SMU: 24V, 150 mA 153690A-02L or later PXIe-4143 Flex SMU: 24V, 150 mA 153697A-01L or later PXIe-4144 Flex SMU: 6V, 500 mA 153697A-02L or later PXIe-4145 Flex SMU:. Control Unit I/O. Manuals. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. •Current Range: -3 A to 3 A. The fast sample rate of the PXIe-4140 can reduce measurement times, capture transient device characteristics, and allow quick I V. •Voltage Range: -200 V to 200 V. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450 ni pxi-5661 ni pxi-5142 ni pxi-2532b ni pxi-2529 ni pxi-5650 ni pxie-5451 ni pxi-5105 ni pxi-5651 ni pxi-2564ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450 ni pxi-5661 ni pxi-5142 ni pxi-2532b ni pxi-2529 ni pxi-5650 ni pxie-5451 ni pxi-5105 ni pxi-5651 ni pxi-2564National Instruments PXIe-4137 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. National Instruments PXIe-4135 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. PXIe-4142 (782430-01) PXI Express: 4: 3. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. In LabVIEW, create a new VI by going to File >> New VI. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Work with our experts to sustain your critical applications. Please contact Artisan Technology Group Sales for configuration pricing and availability. Connecting channels in parallel also adds complexity to wiring and programming, but may make sense in situations where dynamic performance. 1 Hz to 10 Hz, peak to peak), Typical. We have to consider that current can flow between channels through common LO. Table 4. Once data is in MATLAB, you can analyze and visualize that data for tasks such as signal processing, statistical analysis, digital filtering, and curve fitting. ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450 ni pxi-5661 ni pxi-5142 ni pxi-2532b ni pxi-2529 ni pxi-5650 ni pxie-5451 ni pxi-5105 ni pxi-5651 ni pxi-2564Answer: PXIE-4142 NI module This is a problem with the NI-DAQmx8. The table below provides the maximum current and maximum voltage specifications for the different. Here, you can click the Chassis tab and select the PXI Express Chassis you are interested in purchasing. Solution. Min. This page provides dimensional drawings for the PXIe-4142. The user can utilize this output, which gives up to 6 V and 1 A, as a complementary power supply to the. com. The NI 4138/4139 can also be stacked in series or parallel for extended output capabilities. Chassis 2. pxie-2512 PXIE-1435 Company advantage service: 1. NI InstrumentStudio 2022 Q1 Readme. 15 days free replacement for quality problemsNational Instruments PXIe-4143 PXI Source Measure Unit. 10 20 Hz to 20 MHz bandwidth. The NI PXIe-4142/43 source measure units (SMUs) are high-channel-count, high-speed SMUs with four identical SMU channels per PXI Express slot. 6W 786888-01 3620715 Data Sheet + RoHS. Located using the NI Example Finder. Has been engaged in industrial control industry for a long time, with a large number of inventories. 6 W-24 V to 24 V:17 ±1. Table 1. Likewise, in the 100 mA range, resolution can be calculated by multiplying 100 mA by 100 ppm, as. We are using a PXIe-6368 multifunction I/O module. 7 To settle to 0. InstrumentStudio 2019 has the following requirements: Pentium 4 G1 equivalent or later (Intel i5 equivalent or higher recommended) 1024 x 768 screen resolution (1366 x 768 or higher recommended) InstrumentStudio 2019 supports the following operating systems: Windows 7 (SP1) 64-bit. Industry leading, price advantage, quality assurance 3. PXIe-4142. 要. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. Measuring capacitance with PXIe-4142 SMU. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis 6570 Compatibility with Third-party PXI Controller. Price may vary with addition of accessories and services. Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary. For example Ch0 can sink current from Ch2, but as all channels are configured in source mode then this is not correct working regime for the device, which can cause the damage of the channel. The NI PXIe-4138 is a single channel Source Measure Unit that consolidates a digital control loop design with. 3 V rail and 6. Table 1. Initializing an NI-DCPower session with independent channels allows you to use multiple instruments in the same session. ホームページに戻る; Toggle navigation. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. This page provides dimensional drawings for the PXIe-4142. You can find the pinouts at the end of the PXIe chassis user manual based on your model. 15 days free replacement for quality problemsPXIe-4112. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. The NI PXIe-4140 has 4 quadrants; each channel has. SourceAdapt technology demonstration. I have replaced my NI controller with Adlink' PXIe-3985, but self-test in Max has failed. PXIe-4142の分解能は、アパーチャ遅延が100 µsに設定されていると、1,000 ppmに なります。24 Vレンジの分解能は、次の式に示すように、24Vを1,000 ppmで乗算 して計算します。 24 V * 1,000 ppm = 24 V * 1,000 * 1 × 10-6 = 24 mV The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. For more information and a list of procedures, refer to the Calibration Executive Help topic DMM Instrument Standard Considerations . •Source Adapt: Yes. I don't see anything in the NI-DCPower palette that would allow me to do this. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe PXIe-4162 is a single-slot module with one backplane connector. Do not exceed the isolation voltage of the instrument. National Instruments NI PXIe-4142 ; National Instruments NI PXIe-4463 ; National Instruments Categories. Has been engaged in industrial control industry for a long time, with a large number of inventories. You can select PXI Advisor»Start Building Your System. Each SMU offers 4. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to simulate battery cells connected in series using SMU-s. PXIe-4147. National Instruments PXIe-4141 Source Measure Unit (SMU) This item is sealed in the manufacturer's static bag. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 4. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. When the installer completes, select Restart in the dialog box that prompts you to restart,ni pxie-4112/4113のサポート; ni pxi-4132のセルフキャリブレーションサポート; サポートされているハードウェア. This article will explain how to route a signal from a PXI(e) SMU card to the backplane trigger lines on a PXI(e) chassis. For more information about PXI compatibility with PXIe chassis, consult the knowledge base article PXI Card Compatibility With PXIe Chassis . You can also use InstrumentStudio to monitor and control devices being used in external. Diversified models and products, and all kinds of rare and discontinued products 4. 70 KB NI-PXIe-4143 Datasheet 292. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Four-Channel SMU. Diversified models and products, and all kinds of rare and discontinued products 4. The NI PXIe-4142/43 source measure units (SMUs) are high-channel-count, high-speed SMUs with four identical SMU channels per PXI Express slot. PDF DXF 3D CAD Models. PXIe-4147; PXIe-4162; PXIe-4163; Behavior Changes. the PXIe-4142. You can request repair, schedule calibration, or get technical. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The PXIe-5841 and PXIe-5655 ship with the following software options, which you should use to program the devices: RFmx software. It features 4. 5 G Frequency (Hz) Amplitude (dBFS) 1 MΩ Spectral Characteristics20 Table 8. The device has a 25–point D–SUB and male front panel connector. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Industry leading, price advantage, quality assurance 3. Each SMU offers 4-quadrant operation to source or sink up to ±24 V at ±150 mA. Windows Server 2016 64-bit. 2. Thank you for your participation! * Your assessment is very important for improving the workof artificial intelligence, which forms the content of this projectPXIe-5668 Controller module, NI, PXIe-5668 Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. PXIe-4142 User Manual(s) PXIe-4142 Getting Started Guide(s) PXIe-4142 Calibration Procedure(s) Visual Diagrams . com +86 17750010683 . The equation is C=i*t/U. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 3221366881@qq. Re: Recommended approach for PXI control from Python eperez. the PXIe-4142. 14142 0. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 解决方案. Hello, i am trying to measure capacitance with a SMU. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. Note Windows users may see access and security messages during installation. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. When source-measuring, both the NI-DCPower Source Delay and Aperture Time properties affect the sampling rate. NI SMU的数字化仪功能对于捕获SMU详细的瞬态响应特性或表征待测设备(DUT)响应(例如线性调整率和负载调整率)至关重要。. PXIe-4142 configured for normal transient response. This document explains how to install, configure, and test the NI PXIe. PXIe-4142 Dimensional Drawing(s) Regulatory . FOB Price: US $0. Solution Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary waveform to a continuous output sequence with voltage levels and source delays (corrected by the intersample delays of the. 4Channels PXIe-4142 Current/Voltage Measure, Current/Voltage. 2 Channels are isolated from earth ground but share a. NI PXIe-4142 PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit This document contains the verification and adjustment procedures for the NI 4142. Re: Waveform capture on PXI-4142. the PXIe-4142. Email: info@artisantg. Min: 1 Mult: 1. National Instruments PXIe-4142 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 4 •Voltage Range: -24 V to 24 V •Current Range: -150 mA to 150 mA. LabWindows/CVI . MODULE ASSEMBLY,PXIE-4142. Solution. Measured at the end of the 1 m SHDB62M. 7 or higher. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. PXIe-4145. Ensure the AC power source is connected to the chassis before installing the PXIe-4162. •Voltage Range: -200 V to 200 V. 1以降は、次の電源およびsmu(ソースメジャーユニット)をサポートしています。 ni pxi-4110; ni pxie-4112; ni pxie-4113; ni pxi-4130; ni pxi-4132; ni pxie. This page documents all the applicable standards and certifications for the PXIe-4142 and provides downloadable certifications. You can access the software and documentation known issues list online. 2 Channels are isolated from earth ground but share a. ABB; Allen Bradley; BENTLY NEVADA; FOXBORO; GE ELECTRIC;. 0 dropped support for Express VIs in LabVIEW. This documents provides information on calibration service levels available for NI Products. In the 10 V range, resolution can be calculated by multiplying 10 V by 100 ppm, as shown in the following equation: 10 V * 100 ppm = 10 V * 100 * 1×10 -6 = 1 mV. PXIE-4142 PXIE-4141 PXIE-4140 PXIE-4113 PXIE-4112 PXIE-2790 PXIE-2727 PXIE-2725 PXIE-2593 PXIE-2575 PXIE-2569 PXIE-2543. PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent. For example, the NI PXIe-4139 can sample up to 1. NI PXIe-4143 technical details. Has been engaged in industrial control industry for a long time, with a large number of inventories. 5 A from the 3. When taking a measure record, only the Aperture Time property affects the sampling rate. 99 oz and has the dimensions: 0. FOXBORO: I / A Series System: FBM (Field Input / Output Module) Sequence Control, Ladder Logic Control, Incident Recall Processing, D / A Conversion, I / O Signal Processing, Data Communication and. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 7 A from the 12 V rail. GETTING STARTED GUIDE PXIe-4162 PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4162. PXIe-4142: PXIe-4143: PXIe-4144: PXIe-4145: PXIe-4154: PXIe-5122: PXIe-5160: PXIe-5442: PXIe-5451: PXIe-5611: PXIe-5650: PXIe-5651: PXIe-5652: PXIe-5653: PXIe-5665 (14 GHz) PXIe-5665 (3. We have 1 National Instruments PXIe-4610 manual available for free PDF download: Getting Started Manual. NI. •Source Adapt: Yes. 6W. eperez. 3V (there may be mistakes but I hope you get the idea). •Current Sesitivity: 10 pA. The idea is to set the measuring channel's Source Mode to DC Current and set 0A for the current level (or. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 1 x 8. TobiasG. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 7 20 Hz to 20 MHz bandwidth. 92 [] 2X . Each 1+ RM76,925. The National Instruments PXIe-4140 (Part Number: 781742-01) is a Source Measure Unit with four SMU channels. Skip to content. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 55 []-. 2. the PXIe-4142. 148 3. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis Remote sense can be enabled or disabled using the niDCPower Configure Sense VI on a per output basis for channels that support this feature. Note Before you begin, install and configure your chassis and controller. 0. Hey guys, I have one set of NI PXI Platform, the PXI chassis is PXIe-1082, and there're several cards inside it, such as PXIe-6570, PXIe-6368 and PXIe-4142. Resolution (noise limited) Noise (0. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per MonthNI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. National Instruments PXIe-4143 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 4 Voltage Range: -24 V to 24 V Current Range: -150 mA to 150 mA Current Sesitivity: 10 pA Source Adapt: Yes Part Number: 153690A-02L, 782431-01National Instruments PXIe-4139 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. •Voltage Range: -200 V to 200 V. 8 MS/s, giving you the ability to examine the detailed transient characteristics of the SMU output. the PXIe-4142.